English  |  Vietnamese
Loading
Minimum aggression of the coating in the image areas obtaining the maximum cleaning of the non images areas.
Maintaining in the bath the correct conductivity values.
High emulsion dissolving properties to minimize the accumulation of residuals in the automatic processor.
Long life in processor.
Highly recommended for:
Durable Thermal Positive Plate DTP160
Durable Thermal Positive Plate DTP150i
Durable Thermal Positive Plate DTP150eu
Durable Thermal Positive Plate DTP150i+




Plate Highly recommended for Durable Thermal Positive Plate DTP160, Durable Thermal Positive Plate DTP150i,Durable Thermal Positive Plate DTP150eu and Durable Thermal Positive Plate DTP150i+
Application Development in processors for thermal plates. Replenishment
Specifications pH value above 13 and Conductivity between 99 to 101 mS at 25oC
Working temperature 23oC ± 1oC
Replenishment rate 80 ÷ 90 ml/m2
Antioxidant Stand by ON 50 ml/h
Antioxidant Stand by OFF 50 ml/h
Considerations Adequate replenishment keeps filters and circulation systems clean prolonging the life of the bath. Correct cleaning of the equipment will avoid contamination of the new bath and prolong the life of the processor.
Safelight None required - daylight handling
Shelf life 12 months under recommended storage conditions
Packaging 10, 20 liters
Transport and storage Should be stored flat and away from excessive cold, heat and humidity. Use in a controlled environment of 5oC - 30oC and 40 - 80% RH, non- condensing
Availability Contact your local MyLan Group representative. See the list of our Distributors at www.mylangroup.com for contact information.
go to pagetop